| Radioligand Binding Assay |
Description: | Radioligand binding assays (screening and dose-displacement) used 0.1 nM [3H]-nociceptin (NEN; 87.7 Ci/mmole) with 10-20 μg membrane protein in a final volume of 500 μl binding buffer (10 mM MgCl2, 1 mM EDTA, 5% DMSO, 50 mM HEPES, pH 7.4). Non-specific binding was determined in the presence of 10 nM unlabeled nociceptin (American Peptide Company). All reactions were performed in 96-deep well polypropylene plates for 1 h at room temperature. Binding reactions were terminated by rapid filtration onto 96-well Unifilter GF/C filter plates (Packard) presoaked in 0.5% polyethylenimine (Sigma). Harvesting was performed using a 96-well tissue harvester (Packard) followed by three filtration washes with 500 μl ice-cold binding buffer. Filter plates were subsequently dried at 50° C. for 2-3 hours. Fifty μl/well scintillation cocktail (BetaScint; Wallac) was added and plates were counted in a Packard Top-Count for 1 min/well. |
Affinity data for this assay | |
---|---|